Chapter 7 Loading a Variety of Data

5.Turn the VALUE dial or press [ ] or [ ] to select the Sample to be transmitted, then press [F5 (Mark)]. Press

[F4 (Mk All) if you want to set markers in all samples. Press this once more to remove all markers.

*This displays the number and size of marked samples on the display.

6.Press [F6 (Trans)] to initiate the transmission.

The following message appears on the display: “Transmitting....”

*Reception using Sample Dump Standard can only be done in this mode.

Receiving Samples

1.Connect the XV-5080 and the transmitting sampler with a MIDI cable.

For instructions on making the transmitting sampler settings, refer to the owner’s manual for the connected device.

2.Press [SYSTEM/UTILITY], getting its indicator to start blinking.

*If the indicator is steadily lit, you are in SYSTEM mode. Press [SYSTEM/UTILITY] once again, so the indicator is blinking.

3.Press [F6 (Menu)] to select Menu 2.

4.Press the [F2 (S-Dump)] button.

The Sample Dump Standard page appears.

This completes the preparations needed for reception.

5.Transmit the Sample from the transmitting device.

The following message appears in the display: “Receiving....”

Free Area

SIMM

This displays the amount of free space in the SIMM.

Marked

The number and size of marked files to be processed are displayed.

Emphasizing and Suppressing the High End of Loaded Samples (Emphasis)

Emphasizing the high range frequencies in data received in a Sample Dump from another manufacturer’s sampler may improve the sound quality of the samples. Furthermore, when samples (wave data) are transmitted to another manufacturer’s sampler, the high end of the samples may be boosted in the destination device. In such instances, by suppressing the high frequencies prior to transmission, you can minimize the changes in sound quality that could occur as a result of the transmission.

1.Press [SYSTEM/UTILITY], getting its indicator to start blinking.

*If the indicator is steadily lit, you are in SYSTEM mode. Press [SYSTEM/UTILITY] once again, so the indicator is blinking.

2.Press [F6 (Menu)] to select Menu 2.

3.Press [F4 (Emphasis)].

The Emphasis page will appear.

4.Turn the VALUE dial or press [ ] or [ ] to select the sample whose high end is to be emphasized or

suppressed, then press [F4 (Mark)]. Press [F3 (Mk All) if you want to set markers in all samples. Press this once more to remove all markers.

5.If emphasizing the high end, press [F6 (+Emphas)]. If suppressing the high end, press [F5 (-Emphas)].

Free Area

SIMM

This displays the amount of free space in the SIMM.

Marked

The number and size of marked files to be processed are displayed.

Processing

This indicates the approximate time required for processing Emphasis.

192

Page 192
Image 192
Roland XV-5080 owner manual Receiving Samples, Processing, 192