Samsung DCS-408I manual MMC 503 TRUNK-WIDE Timers, 408/408i Other Systems

Models: DCS-408I DCS-408

1 276
Download 276 pages 41.84 Kb
Page 152
Image 152

DCS

MMC PROGRAMS

COMBINED PROGRAMMING MANUAL

NOVEMBER 2001

 

 

 

 

 

 

 

 

 

 

 

 

MMC: 503 TRUNK-WIDE TIMERS

DCS

3

CI

3

CII

3

816

3

408i

3

408

3

Allows certain trunk timer values to be changed on a per-trunk basis or for all trunks. It is not ad- visable to change these values (with the exception of trunk flash time) without assistance from Technical Support.

TIMER

RANGE

DEFAULT

 

DIAL

 

 

 

408/408i

Other Systems

ANS.BAK TM

0100–2500 MSEC

0600 MSEC

00

00

CLEARING

0100–2500 MSEC

2000 MSEC

01

01

CO SUPV TM

0100–2500 MSEC

0400 MSEC

02

02

DTMF DURATION

0100–2500 MSEC

0100 MSEC

03

03

FIRST DGT DELAY

0100–2500 MSEC

0600 MSEC

04

04

FLASH TIME

0100–2500 MSEC

0070 MSEC

05

05

NO RING TM

001–255 SEC

004 SEC

06

06

PAUSE TIME

001–255 SEC

003 SEC

07

07

PRS DET TM

0000–2500 MSEC

0000 MSEC

08

08

RNG DET.TM

0100–2500 MSEC

0300 MSEC

09

09

WINK TIME

0100–0300 MSEC

0200 MSEC

n/a

10

MF/DP INT TM

0100–9900 MSEC

0800 MSEC

10

11

MFR DLY TM

00–25 SEC

00 SEC

11

12

PROGRAM KEYS

 

UP & DOWN

Used to scroll through options

KEYPAD

Used to enter selections

SOFT KEYS

Move cursor left and right

SPEAKER

Used to store data and advance to next MMC

ANS/RLS

Used to select ALL

ACTION

1.Open programming and select 503 Display shows

2.Dial trunk number (e.g., 704)

OR

Press UP or DOWN key to select trunk and press RIGHT soft key to move cursor

OR

Press ANS/RLS to select all trunks and press RIGHT soft key to move cursor

3.Dial timer number from above list

OR

Press UP or DOWN key to select timer and press RIGHT soft key to move cursor

DISPLAY

[701] ANS.BAK TM 0600 MS

[704]ANS.BAK TM

0600 MS

OR

[ALL] ANS.BAK TM 0600 MS

[704]DTMF DUR.

0600 MS _

4.Enter new timer value (must be four digits, e.g., 0700) System returns to step 2

5.Press TRSF to store and exit

OR

Press SPEAKER to store and advance to next MMC

Default Data:

See table above

Related Items:

None

[704]DTMF DUR.

0600 MS 0700

MMC 503 (Page 1 of 1)

Page 152
Image 152
Samsung DCS-408I manual MMC 503 TRUNK-WIDE Timers, 408/408i Other Systems