DCS

MMC PROGRAMS

COMBINED PROGRAMMING MANUAL

NOVEMBER 2001

MMC: 311 ASSIGN SIM PARAMETER

DCS

CI

CII

816

408i

408

Assigns and sets parameters for the serial interface module (SIM). Refer to tables 1–12, below.

PROGRAM KEYS

 

UP & DOWN

Used to scroll through options

KEYPAD

Used to enter selections

SOFT KEYS

Move cursor left and right

SPEAKER

Used to store data and advance to next MMC

HOLD

Used to clear previous entry

ACTION

1.Open programming and select 311 Display shows

2.Enter station number connected to SIM (e.g., 257) from dial keypad

OR

Press UP or DOWN key to make selection and press RIGHT soft key to move cursor

DISPLAY

[256] SIM PARA SIM TYPE :DTE

[257]SIM PARA. SIM TYPE :DTE

3.Enter desired selection from table 1 (00–10, e.g. 01)

OR

Press UP or DOWN key to make selection and press RIGHT soft key to move cursor

Refer to table 1 for your selected option and go to the table indicated (e.g. 3) to enter required

value (e.g. 0) using dial keypad or by pressing UP or DOWN key

Press RIGHT soft key to move cursor

4.Repeat step 3 for all required options (00–10 in table 1)

5.Press TRSF to store and exit

OR

Press SPEAKER to store and advance to next MMC

TABLE 1. SIM PARAMETER

 

00

SIM TYPE

=

Table 2

01

CALL MODE

=

Table 3

02

ANS MODE

=

Table 4

03

AUTO BAUD

=

Table 5

04

DTR CHECK

=

Table 6

05

ECHO

=

Table 7

06

PROTOCOL

=

Table 8

07

SPEED

=

Table 9

08

CHAR LENGTH

=

Table 10

09

PARITY

=

Table 11

10

STOP BIT

=

Table 12

 

 

 

 

[257]SIM PARA. CALL MODE:AWITH

[257] SIM PARA.

CALL MODE:MANUAL

MMC 311 [DCS] (Page 1 of 2)

Page 99
Image 99
Samsung DCS-408I manual MMC 311 Assign SIM Parameter