DCS | MMC PROGRAMS |
COMBINED PROGRAMMING MANUAL | NOVEMBER 2001 |
MMC: 311 ASSIGN SIM PARAMETER
DCS
✓
CI
✗
CII
✗
816
✗
408i
✗
408
✗
Assigns and sets parameters for the serial interface module (SIM). Refer to tables
PROGRAM KEYS |
|
UP & DOWN | Used to scroll through options |
KEYPAD | Used to enter selections |
SOFT KEYS | Move cursor left and right |
SPEAKER | Used to store data and advance to next MMC |
HOLD | Used to clear previous entry |
ACTION
1.Open programming and select 311 Display shows
2.Enter station number connected to SIM (e.g., 257) from dial keypad
OR
Press UP or DOWN key to make selection and press RIGHT soft key to move cursor
DISPLAY
[256] SIM PARA SIM TYPE :DTE
[257]SIM PARA. SIM TYPE :DTE
3.Enter desired selection from table 1
OR
Press UP or DOWN key to make selection and press RIGHT soft key to move cursor
Refer to table 1 for your selected option and go to the table indicated (e.g. 3) to enter required
value (e.g. 0) using dial keypad or by pressing UP or DOWN key
Press RIGHT soft key to move cursor
4.Repeat step 3 for all required options
5.Press TRSF to store and exit
OR
Press SPEAKER to store and advance to next MMC
TABLE 1. SIM PARAMETER |
| ||
00 | SIM TYPE | = | Table 2 |
01 | CALL MODE | = | Table 3 |
02 | ANS MODE | = | Table 4 |
03 | AUTO BAUD | = | Table 5 |
04 | DTR CHECK | = | Table 6 |
05 | ECHO | = | Table 7 |
06 | PROTOCOL | = | Table 8 |
07 | SPEED | = | Table 9 |
08 | CHAR LENGTH | = | Table 10 |
09 | PARITY | = | Table 11 |
10 | STOP BIT | = | Table 12 |
|
|
|
|
[257]SIM PARA. CALL MODE:AWITH
[257] SIM PARA.
CALL MODE:MANUAL
MMC 311 [DCS] (Page 1 of 2)