DCS

MMC PROGRAMS

 

COMBINED PROGRAMMING MANUAL

NOVEMBER 2001

 

 

 

 

 

 

 

 

 

 

 

 

MMC: 204 COMMON BELL CONTROL

DCS

3

CI

3

CII

3

816

3

408i

3

408

3

Determines whether the common bell relay contacts have an interrupted or continuous closure when activated. If interrupted is chosen, the relay follows an internal ring pattern of one second closed followed by three seconds open.

By default, all common bell relay pairs are assigned as:

DCS: 380x

Compact II: 363–365

816:362

408 and 408i: 361

PROGRAM KEYS

 

UP & DOWN

Used to scroll through options

KEYPAD

Used to enter selections

SOFT KEYS

Move cursor

SPEAKER

Used to store data and advance to next MMC

ACTION

1.Open programming and select 204 Display shows current setting

(Note: Display differs according to system)

2.Dial common bell number

OR

Press UP or DOWN key to make selection of common bell numbers and press RIGHT soft key to advance cursor

DISPLAY

[3801]COM. BELL CONTINUOUS

OR

[363] COM/LD BELL CONTINUOUS

3.Dial 0 for continuous or 1 for interrupted operation

OR

Use UP or DOWN to scroll through options Press RIGHT soft key to return to step 2

4.Press TRSF to store and exit

OR

Press SPEAKER to store and advance to next MMC

[3801]COM. BELL INTERRUPTED

OR

[363]COM/LD BELL

INTERRUPTED

Default Data:

Continuous

Related Items:

MMC 203

Assign UA Device

 

MMC 219 Common Relay Service Type

 

MMC 601

Assign Station Group

MMC 204 (Page 1 of 1)

Page 71
Image 71
Samsung DCS-408I manual MMC 204 Common Bell Control, DCS Compact II, 3801COM. Bell Continuous 363 COM/LD Bell Continuous