SMC Networks SMC6824M manual Snmp-server view, show snmp engine-id display description

Models: SMC6824M

1 608
Download 608 pages 58 Kb
Page 454
Image 454

SNMP COMMANDS

Table 4-42 show snmp engine-id - display description

Field

Description

 

 

Local SNMP

String identifying the local engine ID.

engineID

 

 

 

Local SNMP

The number of times that the engine has (re-)initialized since

engineBoots

the snmp EngineID was last configured.

 

 

Remote SNMP

String identifying an engine ID on a remote device.

engineID

 

 

 

IP address

IP address of the device containing the corresponding remote

 

SNMP engine.

 

 

snmp-server view

This command adds an SNMP view which controls user access to the MIB. Use the no form to remove an SNMP view.

Syntax

snmp-server view view-nameoid-tree{included excluded} no snmp-server view view-name

view-name- Name of an SNMP view. (Range: 1-64 characters)

oid-tree- Object identifier of a branch within the MIB tree. Wild cards can be used to mask a specific portion of the OID string. (Refer to the examples.)

included - Defines an included view.

excluded - Defines an excluded view.

Default Setting

defaultview (includes access to the entire MIB tree)

Command Mode

Global Configuration

Command Usage

Views are used in the snmp-server group command to restrict user access to specified portions of the MIB tree.

The predefined view “defaultview” includes access to the entire MIB tree.

4-162