SMC Networks SMC6824M manual Console Port Settings, Command Attributes

Models: SMC6824M

1 608
Download 608 pages 58 Kb
Page 86
Image 86

CONFIGURING THE SWITCH

This example shows how to download a PoE controller file from a TFTP server.

Console#copy tftp file

4-82

TFTP server

IP address: 10.3.4.50

 

Choose file

type:

 

1.config: 2. opcode 3. PD_Controller: <1-3>: 3 Source file name: 7012_007.s19

Destination file name: PoE-test Write to FLASH Programming. Write to FLASH finish.

Success.

Console#

This example shows how to copy a PoE controller file from another unit in the stack.

Console#copy file controller

4-82

Unit <1-2>: 2

Choose controller type:

1.PoE: 2. VDSL: 3. TBD <1-3>: 1 Source file name: PoE-test

Software downloading in progress, please wait...

Unit 1 done Console#

Console Port Settings

You can access the onboard configuration program by attaching a VT100 compatible device to the switch’s serial console port. Management access through the console port is controlled by various parameters, including a password, timeouts, and basic communication settings. These parameters can be configured via the Web or CLI interface.

Command Attributes

Login Timeout – Sets the interval that the system waits for a user to log into the CLI. If a login attempt is not detected within the timeout interval, the connection is terminated for the session. (Range: 0 - 300 seconds; Default: 0)

Exec Timeout – Sets the interval that the system waits until user input is detected. If user input is not detected within the timeout interval, the current session is terminated. (Range: 0 - 65535 seconds; Default: 600 seconds)

3-30

Page 86
Image 86