CONFIGURING THE SWITCH

Web – Click System, Line, Telnet. Specify the connection parameters for Telnet access, then click Apply.

Figure 3-14 Configuring the Telnet Interface

CLI – Enter Line Configuration mode for a virtual terminal, then specify the connection parameters as required. To display the current virtual terminal settings, use the show line command from the Normal Exec level.

Console(config)#line vty

4-14

Console(config-line)#login local

4-15

Console(config-line)#password 0 secret

4-16

Console(config-line)#timeout login response 300

4-17

Console(config-line)#exec-timeout 0

4-18

Console(config-line)#password-thresh 3

4-19

Console(config-line)#end

 

Console#show line

 

4-24

Console configuration:

5 times

 

Password threshold:

 

Interactive timeout: Disabled

 

Login timeout: Disabled

 

Silent time:

60

 

Baudrate:

auto

 

Databits:

8

 

Parity:

none

 

Stopbits:

1

 

VTY configuration:

3 times

 

Password threshold:

 

Interactive timeout:

600 sec

 

Login timeout: 300 sec

Console#