SMC Networks SMC6824M manual Syntax Parity none even odd no parity

Models: SMC6824M

1 608
Download 608 pages 58 Kb
Page 313
Image 313

COMMAND LINE INTERFACE

Default Setting

8 data bits per character

Command Mode

Line Configuration

Command Usage

The databits command can be used to mask the high bit on input from devices that generate 7 data bits with parity. If parity is being generated, specify 7 data bits per character. If no parity is required, specify 8 data bits per character.

Example

To specify 7 data bits, enter this command:

Console(config-line)#databits 7

Console(config-line)#

Related Commands

parity (4-21)

parity

This command defines the generation of a parity bit. Use the no form to restore the default setting.

Syntax

parity {none even odd} no parity

none - No parity

even - Even parity

odd - Odd parity

Default Setting

No parity

Command Mode

Line Configuration

4-21