Performance Tests

Flatness

0.157div., maximum

Fall time

357ns, maximum

6.Move the connection for the coaxial cable from the AWG2005 CH1 output to AWG2005 CH2 output connector.

7.Turn on the AWG2005 CH2 output: Push the CH￿ button so that the LED above the CH2 output connector is on.

8.Repeat procedures 4 through 5.

9.If Option 02 is installed (add CH3 and CH4 output channels: Repeat above procedure for the AWG2005 CH3 and CH4 output channels.

10.End procedure: Remove the connections.

MARKER OUT

This procedure checks the amplitude of the MARKER OUT signal.

Amplitude Check

 

 

Electrical Characteristic Checked: Auxiliary Output, MARKER, Ampli8

 

tude, on page71814.

 

Equipment Required: A 507Ω coaxial cable and an oscilloscope.

 

Prerequisites: The AWG2005 meets the prerequisites listed on page 487.

Procedure:

1.Install test hookup and set test equipment controls:

a.Hook up the oscilloscope: Connect the AWG2005 rear8panel CH1 MARKER OUT connector through the coaxial cable to the CH1 vertical input connector on the oscilloscope (see Figure 4816).

AWG2005

Oscilloscope

AWG2005

Figure 4)16:(Initial Test Hookup

b.Set oscilloscope controls:

4￿36

Performance Verification