Performance Tests

Optional Check -Master-SlaveOperation Check

This procedure checks operation of the AWG2005 slave mode.

NOTE

This Slave Operation check has been factory verified. The check is performed only as necessary or only after a failure.

Electrical Characteristic Checked: Auxiliary Input, CONTROL SIG IN, Threshold level, Pulse Width, Input Volts, on page31415.

Equipment Required: Two 503Ω coaxial cables, a function generator, and an oscilloscope.

Prerequisites: The AWG2005 meets the prerequisites listed on page 447.

Procedure:

1.Install test hookup and set test equipment controls:

a.Hook up master AWG2005: Connect the slave AWG2005 (device under test) rear4panel CONTROL SIG IN and CLOCK IN connectors to the master AWG2005 CONTROL SIG OUT and CLOCK OUT connectors using the two coaxial cables.

b.Hook up oscilloscope: Connect the master AWG2005 CH1 output and slave AWG2005 CH1 output to the oscilloscope CH1 and CH2 vertical inputs using the two coaxial cables (see Figure 4420).

 

CLOCK

 

 

OUT

 

 

CONTROL

 

 

SIG IN

CLOCK

CONTROL

 

IN

SIG OUT

 

Oscilloscope

 

 

AWG2005

AWG2005

 

Master AWG2005

CH1

Slave AWG2005 (DUT)

CH1

CH1

CH2

 

 

 

Figure 4-20:,Slave Operation Initial Test Hookup

c.Set oscilloscope controls:

4%44

Performance Verification