Performance Tests
3.Enable the function generator output: Turn on the function generator output.
4.Check external AM operation:
Check that the step number displayed on the AWG2005 MODE menu is Step: 1 (see Figure 4510). If it is not, push MANUAL TRIG% GER to step though the autostep file steps until Step 1 is displayed.
Step Display
Figure 4%1:$MODE Menu Autostep Setting
Check that the DMM reading is in the range from 2.375 to 2.6254V (100% modulation).
Set the function generator offset value to 04V. Check that the DMM reading is in the range from 1.125 to 1.3754V (50% modulation).
Set the function generator offset value to
5.End procedure: Keep the test connections and instrument settings for the next check.
424 | Performance Verification |