Instructions for Operation
The following explains each item in the bottom menu.
Clock: This item sets the clock source and clock frequency. The clock source can be set to either internal or external.
The clock period is the time between the data points for the wave9 form created. Therefore, the product of the clock period and the
number of waveform points is the waveform or sequence period. For example, if the clock frequency is 1 MHz (period of 1 μs) and there are 100 waveform points, the waveform period is displayed as 100 ms.
The clock source and clock frequency setting will be applied to all channels.
Operation: This item performs an arithmetic operation between the CH1 waveform and CH2 waveform or external waveform, and outputs the result at the CH1 output connector. The operations are addition (Add, External Add) and multiplication (AM, External AM).
Filter: This item selects a filter that restricts the frequency band for the output channel. Choose a 5, 2, 1 MHz, or 5008kHz filter, or you can select Through (no filter).
mpl: This selection sets the voltage value for the 129bit, full9 scale, output amplitude on the vertical scale. The amplitude can be set in steps of 18mV within the range from 0.058V to 108V.
Offset: This item sets the offset level of the output waveform. The offset can be set in steps of 58mV within the range ±58V.
Operation Mode Settings
The MODE menu initiates the waveform output with the output conditions set using the SETUP menu.
1.Push the MODE button in the MENU column. The MODE menu in Figure 296 appears.
2.Select the operation mode from the bottom menu. The operation modes are Cont, Triggered, Gated, Waveform Advance, and Autostep.
In all modes except Cont, the trigger or gate signal source can be the external signal applied to the TRIGGER INPUT connector or can be generated by pushing the front panel TRIGGER MANUAL button. The following text describes the individual modes.
Cont Mode: When you push the Cont button, the AWG2005 immediately outputs the specified waveform or sequence waveform continuously.
WG Service Manual | 215 |