AT-WA7500 and AT-WA7501 Installation and User’s Guide

Example: To change the inactive boot and data segments to active at the next reboot, enter:

sdvars set setactivepointers both

sdvars set nextpoweruptime

Purpose: Sets the nextpoweruptime command to set the internal variable nextpoweruptime to a countdown time so that when 0 is reached, the access point will reboot. When the nextpoweruptime counter reaches 0, the access point checks the value of the setactivepointers variable, takes the appropriate action, and then reboots.

Note

If you need to terminate the reboot, you can set nextpoweruptime to 0 if it has not already been reached by the countdown. By resetting nextpoweruptime to 0, the timer stops so the access point does not reboot.

Syntax: sdvars set nextpoweruptime dd:hh:mm:ss

where dd:hh:mm:ss is how far in the future the reboot is to begin and

ddis days.

hhis hours.

mmis minutes.

ssis seconds. Example:

To reboot the access point 2 hours from now, enter:

sdvars set nextpoweruptime 00:02:00:00

287

Page 287
Image 287
Allied Telesis AT-WA7501, AT-WA7500 manual Sdvars set nextpoweruptime