AT-WA7500 and AT-WA7501 Installation and User’s Guide

For this example, set these filter expressions.

Table 23. Example 1 – Filter Expressions

Parameter

Value

Explanation

 

 

 

 

 

 

ExprSeq

10

The order that you want the expressions

 

 

executed. You must have an expression

 

 

for each Value ID that is listed in the Filter

 

 

Values menu.

 

 

 

Offset

0

Since the filter is applied to the destination

 

 

address, which is the first value in the

 

 

frame, the offset is 0.

 

 

 

Mask

ff ff ff ff ff ff

Compares the entire 6-byte destination

 

 

address for an exact match.

 

 

 

Op

EQ

Compares the value after the offset and

 

 

mask are applied to the value of the Value

 

 

ID from the Filter Values menu to see if

 

 

they are equal. (If the value at the offset

 

 

equals the specified value on the Filter

 

 

Values menu, the frame is multicast.)

 

 

 

Value ID

1

This filter expression applies to value ID 1

 

 

from the Filter Values menu.

 

 

 

Action

Pass

If this filter expression is true, continue to

 

 

the next expression.

 

 

 

You must enter a filter expression for each Value ID in the Filter Values menu. In this example, only the ExprSeq and the Value ID values change.

91

Page 91
Image 91
Allied Telesis AT-WA7501, AT-WA7500 manual Parameter Value Explanation