SE RVICE MODE AND E RR O R CO DES

EMERG ENCY OPE RATI ON

In the even t of an error code , the Combith er m may be oper ated on a limited basis. Error conditions und er whi ch conti nued opera tion can be conducted are indicated by “Yes” in the chart shown below.

Whe n the oven malfunc tion s, an error cod e will appea r in the displa y.

PRES S THE START KEY TO ACKNOWLEDGE THE ERROR.

The keys that begi n to flash represent oper ation al modes that are still usable.

SELEC T AND PRESS ONE OF THE COOKING MODE S INDICA TED.

The oven cont rol will only respond to the mode keys that are flas hin g.

SET THE OVEN CONTROLS AS IF OPERATING UNDER NORMA L CIRCUMSTANCES.

Depen ding on the err or code inv olved, oven funct ion , such as temperatu re range, may be limited .

PRES S THE START KEY TO BEGIN THE COOKING PROCES S.

PRES S THE START KEY WHE N THE TIMER EXPIRE S.

Whe n the oven fault is correc ted, the Comb ith erm wil l retu rn to normal Operation.

CONTI NUE D OPERATION UNDER ERROR CONDITIO NS

Error

 

 

Display Shows

ES

ESi

Steam

Combination

Convection

Retherm

Code

 

 

 

 

 

 

Mode

Mode

Mode

Mode

 

 

 

 

 

 

 

 

 

E01

Low Water

 

Yes

No

No

No

To 365°F

No

 

 

 

 

 

 

 

 

 

E02

Control

Temp High

Yes

Yes

Yes

To 284°F

To 284°F

To 284°F

 

 

 

 

 

 

 

 

 

E03

Fan Malfunction

 

No

No

 

 

 

 

 

 

 

 

 

E04

Aux Fan Fault

 

Yes

Yes

Yes

To 284°F

To 284°F

To 284°F

 

 

 

 

 

 

 

 

 

E11

Excess

Oven Temp

Yes

Yes

No

No

No

No

 

 

 

 

 

 

 

 

 

E13

Excess

Steam Gen Temp

Yes

No

No

No

No

No

 

 

 

 

 

 

 

 

 

 

E15

Excess

Condensate

Temp

Yes

Yes

No

No

To 356°F

No

 

 

 

 

 

 

 

 

 

 

E21

Oven

Probe Fault

 

Yes

Yes

212°F only

No

No

No

 

 

 

 

 

 

 

 

 

 

E22

Core

Temp Probe

Fault

Yes

Yes

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

 

E23

Steam

Gen Probe

Fault

Yes

No

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

E24

Bypass

Probe Fault

Yes

Yes

To 210°F

No

Yes

No

 

 

 

 

 

 

 

 

 

E25

Condensate Probe

Fault

Yes

Yes

Yes

To 356°F

To 356°F

To 320°F

 

 

 

 

 

 

 

 

E26

Steam Gen Safety Probe Fault

Yes

No

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

E27

Excess Steam Gen Safety Temp

Yes

No

No

No

No

No

 

 

 

 

 

 

 

 

 

E29

Probe

Short to Frame

Yes

Yes

No

No

No

No

 

 

 

 

 

 

 

 

E34

DE (Drain) Pump Failure

Yes

No

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

 

E35

Venting

Error

 

Yes

Yes

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

 

E36

Steam

Temp High

 

No

Yes

No

No

Yes

No

 

 

 

 

 

 

 

 

 

E80

ID Error

 

Yes

Yes

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

E81

Program Memory

Error

Yes

Yes

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

E82

WP Error

 

Yes

Yes

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

 

E83

Algo

Error

 

Yes

Yes

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

E96

Connection Error

 

Yes

Yes

No

No

No

No

 

 

 

 

 

 

 

 

 

 

 