Service Mode 1 (230/250C) | Service Mode 1 (330/350C) |
(Details ' page | (Details ' page |
Align | Form |
Cartridges | Feed |
+ | + |
Stopping most Tests | |
(Details ' page |
|
| Shift |
+ |
|
| |
Quality |
|
Some of the tests in service mode 1 send test information to the plotter's serial port. To view the information on an HP Palmtop PC, perform the procedure below.
1Turn the plotter and Palmtop off.
2Use HP cable number F1015.80002 and adapter number 5181.6640 to connect the Palmtop to the plotter's serial interface port.
Both cable and adaptor are included in the HP F1021B Connectivity Pack.
3Turn the plotter on in service mode 1.
4Turn the Palmtop on.
5Open the Data Comm application on the Palmtop.
6Press MENU.
7Move to the Connect menu and press ENTER.
8Ensure that Settings are the same for both plotter and Palmtop.
9Again move to the Connect menu and press ENTER.
10With Connect highlighted in the Connect menu, press ENTER.
11Perform the service tests on the plotter.
To stop communication between the plotter and the Palmtop, highlight Hangup in the Connect menu and press ENTER.
8.36 Troubleshooting | C4699.90000 |