Removing the Media Motor

1Remove the spittoon ' page 6/23/6/24.

2Disconnect the media/motor cable and the flat media/axis/encoder cable from the main PCA (connectors labeled MOT X and ENC X respectively), and from the clip at the back of the plotter.

3Remove the two screws that secure the media motor to the media/motor mount.

Torx-15

4Pull the media motor out through the back of the plotter.

Reassembling: The worm pinion and drive!roller gear mesh slightly during use. Don't install a new motor and an old gear, or vice versa: install the gear that comes with the motor. Apply the grease that comes with the new motor to the worm pinion and drive!roller gear.

Calibration: After having reassembled the plotter, perform the accuracy calibration (Details ' chapter 7.)

6/26 Removal￿and￿Replacement

C4699/90000