Flashing6
Flashing9
Flashing13
Flashing23
Load Media: The plotter has a file in memory, which it is waiting to plot, but no sheet is loaded.
Load a sheet.
Ready: The plotter is busy with a task or is receiving a file.
Wait.
Paper + Error: The current plot is too large and does not fit in memory.
D If the plot is a raster plot, try sending it with a no negative motion RTL command. D If it is a vector plot, try using a driver that performs all the rasterization of the plot in the host computer before sending it to the plotter. (See also ' chapter 5, w Memory Usage.) D Otherwise, add more memory by installing a DRAM SIMM.
Cartridges + Error: One or more of the cartridges missing or making bad contact.
D Remove each cartridge. Ensure that the protective tape has been removed, and look for dirty contacts or wear. Replace each cartridge and run the Black7Cartridge Alignment Procedure. (Instructions ' User's Guide, chapter1.) D Replace the trailing cable. D Replace the carriage.
D Replace the electronics module.
Cartridges + Ready: The plotter is testing and servicing the cartridges.
Wait.
Flashing29
C4699790000 | Troubleshooting 877 |