Choosing a Suitable Plotter Environment

(Instructions ' User's Guide, chapter 1, w Position the plotter.)

Environmental Specifications

Hardware:

 

Environmental Class B2

 

Operating environment:

Temperature

Relative Humidity

Plotter

 

0 to 55_C (32 to 131_F)

5-25%

With cartridges and media:

15 to 35_C (59 to 95_F)

20-80%

Storage environment:

Temperature

Relative Humidity

Plotter/media

 

±40 to +70_C

 

 

 

(±40 to +158_F)

5-95%

Cartridges

 

±40 to +40_C

 

 

 

(±40 to +104_F)

 

Acoustics:*

 

Sound Pressure

Sound Power

Operating

D/A1-size plotters

43 dB (Acoustic)

6.0 bels (A)

 

E/A0-size plotters

45 dB (A)

 

Idle

 

< 20 dB (A)

< 3.6 bels (A)

*These specifications are typical sound pressures at a one,meter bystander position. Idle specification assumes fan is off.

Plotter Dimensions and Weight

Plotter Model:

D/A1-size plotters

E/A0-size plotters

 

 

 

Length

1028 mm (40.5 in)

1327 mm (52.2 in)

Depth

237 mm (9.3 in)

237 mm (9.3 in)

Height (window closed)

327 mm (12.9 in)

327 mm (12.9 in)

Weight

26 kg (57.2 lb)

31 kg (68.2 lb)

C4699,90000

Site￿Planning￿and￿Requirements 2,3￿