Steady￿369

Steady￿1234

Steady￿1235

Steady￿1345

Steady￿1346

Steady￿1348

Steady￿1359

Error + Ready + Roll: Library Error.

Special firmware error. See Steady 1389.

Plain + Load Media + Error + Film: Problems in the free movement of the carriage.

The possible causes could be: D Something is causing excessive friction in the Y5axis (carriage axis). D The carriage touches the bail as it moves.

Plain + Load Media + Error + Fast: Error detected in media5axis servo feedback loop.

The problem may be with the: D Media5motor encoder cable D Media motor D Electronics module.

Plain + Error + Film + Fast: Not enough memory for the sensor data structure.

D Turn the plotter off, and then on again to see if the problem disappears.

D If the problem remains, consult recent service notes for a possible solution. D If no service note deals with this error, report the problem to your HP Response Center. Note conditions and actions before error occurred. Include setup sheet and service configuration plot in report.

Plain + Error + Film + Ready: Failure of Centronics READ.

Firmware error or faulty electronics module.

Plain + Error +Film + Normal: Electrical error

The possible causes could be: D Missing or badly seated cartridge. D One end of the trailing cable is not connected or is badly connected, or the trailing cable is faulty. D Faulty fan, or fan is disconnected. D Faulty carriage PCA.

D Faulty main PCA.

Plain + Error + Fast + Roll: Communication broken between the two processors on the main PCA.

Replace the electronics module.

C4699590000

Troubleshooting 8517￿