10Slide the carriage to the right￿ and remove it with the belt from the plotter.

Reassembling￿ Position the belt under the back extrusion of the carriage.

Make sure that you correctly reconnect the trailing cable ' page 6,35.

After reassembling, make sure that you check the carriage,to,media distance ' page 7,11.

Calibration￿ After having reassembled the plotter, perform the black cartridge,alignment. (Details ' User's Guide.)

Removing the Drive Belt

1Remove the cartridge carriage ' page 6#￿7.

2Release the belt from the clips on the underside of the carriage.

Reassembling￿ Clip the belt to the carriage, using the same part of the belt as was originally used. Also, match the vertical lines on the belt with the vertical grooves on the carriage. The horizontal lines on the belt face outwards.

C4699#90000

Removal￿and￿Replacement 6#￿9￿