U T I O N | If you clear the calibration parameters, you will then need to perform the plotter |
| calibrations. (Details ' chapter 7.) Clearing the EEROM also resets the factory |
| spittoon value to 0% used. Keep in mind that the value printed on the service |
| configuration plot may greatly underestimate the amount of ink in the spittoon. |
| Read Settings |
Cea!ig J$"# #he Bech!$ ad Caib!a#i Pa!ae#e!"
1Switch the plotter off.
2While holding both the Read Settings and Media Type keys down switch the plotter on.
3Once the the LEDs begin to light up one by one release the
Read Settings and Media Type keys.
Cea!ig J$"# #he U"e!%Defied Se#$ Pa!ae#e!"
1Switch the plotter off.
2While holding both the Align Cartridges and Print Quality keys down switch the plotter on.
3Once the the LEDs begin to light up one by one release the
Align Cartridges and Print Quality keys.
Cea!ig A Pa!ae#e!"
1Switch the plotter off.
2While holding both the Cancel and Replot keys down switch the plotter on.
3Once the the LEDs begin to light up one by one release the
Cancel and Replot keys.
Media Type
Align Cartridges
Print Quality
Replot
Cancel
8&4 Troubleshooting | C4699&90000 |