Sensors Test for the DesignJet 330 and 350C

This tests the operation of the cover sensor and the media sensor.

1In service mode 1, press Sensors Test.

2Lower the pinch(arms (raise the green media lever)

The Roll LED should turn on.

3Raise the pinch(arms (lower the green media lever) The Roll LED should turn off.

4Close the cover of the plotter. The Ready LED should turn on.

5Open the cover.

The Ready LED should turn off.

6Insert media into the right(hand side of the entry platen. The Coated LED should turn on.

7Remove the media.

The Coated LED should turn off.

St￿tus￿ The LED meanings are summarized as follows:

Sensors Test

Roll

Ready

Coated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cover closed, and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Media present,

 

 

 

 

 

 

 

 

 

 

 

 

 

sensor OK

 

 

 

 

 

 

 

 

 

 

 

 

 

Media not present,

and sensor OK

 

 

 

 

 

 

 

 

 

 

 

 

or sensor failed

 

 

 

 

 

 

 

 

 

 

 

Pinch-arms lowered and sensor OK

8Press the Shift key when you want to stop the test.

Cover open, or

sensor failed

Pinch-arms raised

or sensor failed

Shift

8(48 Troubleshooting

C4699(90000