This tests the operation of the cover sensor and the media sensor.
1In service mode 1, press Sensors Test.
2Lower the pinch(arms (raise the green media lever)
The Roll LED should turn on.
3Raise the pinch(arms (lower the green media lever) The Roll LED should turn off.
4Close the cover of the plotter. The Ready LED should turn on.
5Open the cover.
The Ready LED should turn off.
6Insert media into the right(hand side of the entry platen. The Coated LED should turn on.
7Remove the media.
The Coated LED should turn off.
Sttus The LED meanings are summarized as follows:
Sensors Test
Roll
Ready
Coated
|
|
|
|
|
|
|
|
|
|
|
|
|
| Cover closed, and |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| ||||||||
Media present, |
|
|
|
|
|
|
|
|
|
|
|
|
| sensor OK |
|
|
|
|
|
|
|
|
|
|
|
|
| Media not present, | |
and sensor OK |
|
|
|
|
|
|
|
|
|
|
|
| or sensor failed | |
|
|
|
|
|
|
|
|
|
|
|
8Press the Shift key when you want to stop the test.
Cover open, or
sensor failed
or sensor failed
Shift
8(48 Troubleshooting | C4699(90000 |