Carriage Test for the DesignJet 330 and 350C

This tests the operation of the carriage sensor and the connection between the carriage flex circuit and the cartridges.

1Position the sensor over a white surface. (Simply place a piece of white paper under the sensor.)

2In service mode 1, press Carriage Test.

The plotter varies the LED intensity between 255 and 0.

The plotter tests the connection between the carriage flex circuit and the cartridges by getting the cartridge identification and checking the electrical continuity for all nozzles.

Carriage

Test

The plotter also tests the encoder sensor. Because the encoder sensor only detects motion, it is necessary to manually move the carriage along the encoder strip to correctly perform the test.

Status. During the test, the Load Media, Error and Normal LEDs turn on (steady) if the carriage test has not found an error. If the test fails, one, two or all of these LEDs flash as indicated below:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All OK

 

 

Optical Sensor

 

 

 

 

Flex-Circuit

 

 

 

Encoder

 

 

 

All Failed

 

 

 

 

 

Failed

 

 

Connection Failed

 

 

Sensor Failed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output to the Serial Port (Viewing Output ' 8-36)

In order to send output to the serial port, it is necessary to set the Verbose mode ON. This can be done using the iverbose 1;i underware.

Error code:

If an error has occurred in the sensor test, this code specifies more

 

precisely what has gone wrong. Include this information in the

 

report to your HP Response Center, if the problem cannot be fixed.

 

Pen 0 = Cyan; Pen 1 = Magenta; Pen 2 = Yellow; Pen 3 = Black.

Sensor sensitivity:

The sensitivity measured during the test. The figures should vary

 

from 255 to 0. Failure occurs when the sensitivity does not vary

 

(for example, it stays at 255).

Pen ID:

If a pen does not fail, the plotter outputs the pen ID.

3

The test continuously repeats itself until you

 

 

 

 

Shift

 

 

 

 

 

press the Shift key.

8+40 Troubleshooting

C4699+90000