8Pull the electronics module to the right, in order to easily access the connectors.

9Disconnect all cables from the visible part of the main PCA.

C

B

A

Reassembling￿ The connectors and cables correspond as follows:

Connector

Cable

Clip

FP

Front Panel

A

PINCH

Pinch7Arm Sensor

A

COVER

Top7Cover Sensor

A

MEDIA

Media Sensor

B

P1

Trailing Cable

 

ENC X

Media Motor Encoder

 

MOT X

Media Motor

C

MOT Y

Carriage Motor

C

Prevent tugging on the cables at the point of connection by leaving slack between the connectors and the clips.

10Pull the electronics module further to the right and out of the plotter.

Reassembling￿ Slide the module into the plotter until it is stopped by its location hook on the floor of the plotter. Be careful not to damage the parallel7port clamps.

11If you are changing the electronics module for a new one, remove the DRAM SIMM(if installed) from the old module and install it into the new one. Refer to Chapter 9 before installing the ROM SIMM from the old module into the new module.

Calibrations￿ After having installed a new electronics module, perform the following calibrations. (Details ' chapter 7.)

1.Black Cartridge Alignment

2.Color Cartridge Test

3.Accuracy Calibration

Note also that the factory spittoon value on the EEROM of the new electronics module is reset to 0% used. Keep in mind that the value printed on the service configuration plot may greatly underestimate the amount of ink in the spittoon. Future PC7based plotter diagnostics will enable you to download information from the old EEROM and upload it to the new EEROM.

Reassembling￿ After reinstalling the electronics module, the plotter must be configured with the correct model ID. To configure plotter ' page 8728.

6)14 Removal￿and￿Replacement