Service Configuration Plot for the DesignJet 230 and 250C

The ￿e￿￿ice config￿￿a￿ion plo￿ con￿ain￿ ￿he following info￿ma￿ion:

DesignJet 230/250C Service Configuration Plot

Firmware Release: X.XX.XX

SPROC release: X.X (Servo-Processor Code revision number.)

EEROM Contents

EEROM CONTENTS

(This is for the plotter design engineers to interpret.)

NOTE: All EEPROM Parameters are since last EEROM Reset.

Number of Power Cycles: (Number of times plotter has been switched on.)

Number of Color Plots:

Number of Black Plots:

Number of Pens: (Number of times each cartridge has been replaced. Cyan, Magenta, Yellow, Black.)

Factory Spittoon: (The estimated level of ink in the spittoon. Incorrect if you have cleared the EEROM.) Number of Bail Errors:

Number of System Errors:

Last System Error: (To correctly interpret this information, refer to page 8-19.)

Last System Error Data: (To correctly interpret this information, refer to page 8-19.)

Bench Run: (Whether the bench run has been performed.)

Bench Run Maximum Y-Axis(Carriage-Axis) PWM: (This should be less than 102. Typical value = 75.)

Bench Run Maximum X-Axis(Media-Axis) PWM: (This should be less than 65. Typical value = 52.)

Encoder-Tests Maximum Y-Axis(Carriage-Axis) PWM: (This should be less than 102. Typical value = 75.)

Encoder-Tests Maximum X-Axis(Media-Axis) PWM: (This should be less than 65. Typical value = 52.)

Last Accuracy Calibration:

Factory Calibration Factor:

(This is the drive-roller correction factor, calculated during accuracy calibration. It should be approximately 1. Less than 0.9 means the drive-roller radius is too small. Greater than 1.1 means the drive-roller radius is too big.)

FRONT-PANEL KEYS IN SERVICE MODE 2

C4699￿90000