User Manual for the NETGEAR 7300S Series Layer 3 Managed Switch Software

Modes

Global Config

 

Interface Config

cos-queue strict

This command activates the strict priority scheduler mode for each specified queue.

Format

cos-queue strict <queue-id-1> [<queue-id-2> … <queue-

 

id-n>]

Modes

Global Config

 

Interface Config

no cos-queue strict

This command restores the default weighted scheduler mode for each specified queue.

Format

no cos-queue strict <queue-id-1> [<queue-id-2>

 

<queue-id-n>]

Modes

Global Config

 

Interface Config

random-detect

This command is used to enable WRED for the interface as a whole, and is only available when per-queue WRED activation control is not supported by the device. Specific WRED parameters are configured using the 'random-detect queue-parms' and the 'random-detect exponential- weighting-constant' commands.

Format

random-detect

Modes

Global Config

 

Interface Config

no random-detect

This command disables WRED, thereby restoring the default tail drop operation for all queues on the interface.

Format

no random-detect

Modes

Global Config

 

Interface Config

Quality of Service (QoS) Commands

11-43

202-10088-01, March 2005

Page 307
Image 307