Section 8: Adjustment Procedures

OFFSET LABEL STOP POSITION ADJUSTMENT

The following procedure provides for fine adjustment of the label stop position for Tear-Off, Cutter, and Dispense Modes. The Feed/Backfeed is adjusted with the Offset potentiometer located on the front panel. The Offset adjustment range is +/- 3.75 mm.

NOTE: Figure 10-5, Accessories & Sensors Location; Figure 10-6, Print Position Reference Diagram; and Figures 10-7 through 10-19, Print Operation Sequence in the Diagram & Schematics Section provide additional instruction.

NOTE: Only the stop position is changed with the Offset potentiometer. The print position is changed using the Pitch potentiometer.

1 Turn the OFFSET potentiometer to the center position.

NOTE: The Offset potentiometer is located on the Operator Panel of the front housing cover.

2Press and hold the FEED key while switching on the printer.

3When the printer beeps, release the FEED key.

 

 

 

 

 

LCD DISPLAY:

INITIALIZING ROM V00.00.00.00

 

 

 

 

 

 

 

 

 

 

LCD DISPLAY:

TEST PRINT MODE

 

 

 

CONFIGURATION

 

 

 

 

 

4 Press the FEED key to advance to the next screen.

 

 

 

 

 

LCD DISPLAY:

TEST PRINT SIZE

 

 

 

10CM

 

 

 

 

 

5Press the LINE key to advance the counter to the desired setting.

6Press the FEED key to begin test printing. Press the FEED key again to stop test printing.

7Readjust the OFFSET potentiometer as necessary until proper positioning is achieved.

LCD DISPLAY ADJUSTMENT

This procedure allows illumination intensity adjustment of the LCD display. Adjustment is performed by use of the DISPLAY potentiometer located on the Operator Panel of the front housing cover.

1 Turn on the printer.

2Confirm that the LCD is illuminated and a message is displayed.

3Adjust the DISPLAY potentiometer as necessary achieved the desired setting.

M84Pro Service Manual

PN 9001111A

Page 8-14

Page 110
Image 110
SATO M84PRO service manual Offset Label Stop Position Adjustment, LCD Display Adjustment