Section 5: Printer Configuration
Stop Bit Selection (DSW1-4):Selects the number of stop bits to end each byte transmission.
| | | | | DSW1 |
| DSW1-4 | SETTING | |
| | | | | ON |
| | | | |
| Off | 1 | Stop Bit | |
| | | | | OFF |
| On | 2 | Stop Bits | |
| | | | | |
| | | | | |
1 2 3 4 5 6 7 8
Baud Rate Selection (DSW1-5,DSW1-6):Selects the data rate (bps) for the RS232 port.
| | | | | DSW1 |
| DSW1-5 | DSW1-6 | SETTING | |
| | | | | ON | | | | | | | | |
| Off | Off | 9600 | | | | | | | | | |
| | | | | OFF | | | | | | | | |
| Off | On | 19200 | | | | | | | | | |
| | | | | | | | | | | | | |
| On | Off | 38400 | | | 1 2 3 4 5 6 7 8 |
| | | | | | | | | | | | | |
| On | On | 57600 | | | | | | | | | | |
| | | | | | | | | | | | | |
| | | | | | | | | | | | | |
Protocol Selection (DSW1-7,DSW1-8):Selects the flow control and status reporting protocols. Refer to the Interface Specifications section in this manual for more information. (* Will select the Status 2 protocol if DSW2-8 is ON).
| | | | | DSW1 |
| DSW1-7 | DSW1-8 | SETTING | |
| | | | | ON | | | | | | | | |
| Off | Off | Rdy/Bsy | |
| | | | | OFF | | | | | | | | |
| Off | On | Xon/Xoff | | | | | | | | | |
| | | | | | | | | | | | | |
| On | Off | Bi-Com 3 | | 1 2 3 4 5 6 7 8 |
| | | | | | | | | | | | | |
| On | On | Bi-Com 4 | | | | | | | | | | |
| | | | | | | | | | | | | |
| | | | | | | | | | | | | |
M84Pro Service Manual | PN: 9001111A | Page 5-2 |