Figure 7-8, Fuse Replacement
MOTOR REPLACEMENT
The stepper motor transmits motion to the print mechanism for precise print positioning. The energized motor provides torque to the label feed roller, the platen roller, the ribbon feed roller, and the ribbon rewind spindle via a series of toothed timing belts and gears.
1Switch off the printer and disconnect the power supply cord.
2Open/remove the front, top, right, and left housing covers.
NOTE: Figure
3 Locate motor (1, Figure
NOTE: The left side of the printer contains the circuit board, power board, and gear configuration. The motor is located on the lower side of the gear configuration and the motor’s mounting screws are oriented diagonally from each other on the upper and lower sides of the motor spindle.
4 Remove two screws (2) securing motor (1) to the printer frame.