Section 7: Replacement Procedures
LABEL POSITION SENSOR REPLACEMENT
1Switch off the printer and disconnect the power supply cord.
2Open or remove the top, left, right, and front housing covers.
NOTE: Figures
3 Remove ribbon and media to provide free access to label position sensor (1, Figure
1
4
3
2
Figure 7-17, Label Position Sensor Replacement
4 Remove screw (2) and nylon spacer (3) securing sensor (1) to media sensor guide (4).
NOTE: The sensor is attached to the underside of the sensor guide. The sen- sor guide is manufactured of black phenolic material and is attached to the brass auger type spindle.
5Disconnect wiring harness of damaged sensor (1) from the main circuit board.
6Connect the wiring harness of replacement label position sensor (1) to main circuit board. Refer to Figure
7Reconnect power supply cord, test cycle, and reattach/close all covers.
NOTE: Figures
M84Pro Service Manual | PN 9001111A | Page |