Section 7: Replacement Procedures

LABEL POSITION SENSOR REPLACEMENT

1Switch off the printer and disconnect the power supply cord.

2Open or remove the top, left, right, and front housing covers.

NOTE: Figures 10-1, 10-2, and 10-3 of the Daigrams & Schematics section provides guidance on housing cover, media, and ribbon removal.

3 Remove ribbon and media to provide free access to label position sensor (1, Figure 7-17).

1

4

3

2

Figure 7-17, Label Position Sensor Replacement

4 Remove screw (2) and nylon spacer (3) securing sensor (1) to media sensor guide (4).

NOTE: The sensor is attached to the underside of the sensor guide. The sen- sor guide is manufactured of black phenolic material and is attached to the brass auger type spindle.

5Disconnect wiring harness of damaged sensor (1) from the main circuit board.

6Connect the wiring harness of replacement label position sensor (1) to main circuit board. Refer to Figure 7-18 for guidance.

7Reconnect power supply cord, test cycle, and reattach/close all covers.

NOTE: Figures 10-1, 10-2, and 10-3 of the Daigrams & Schematics section provides guidance on housing cover, media, and ribbon installation.

M84Pro Service Manual

PN 9001111A

Page 7-22

Page 90
Image 90
SATO M84PRO service manual 17, Label Position Sensor Replacement