Section 5: Printer Configuration
Back-Feed Selection (DSW3-4):When Back-Feed is enabled, the printer will position the last printed label for dispensing and retract it before printing the next label. The amount of backfeed offset is adjustable.
| | | |
| DSW3-4 | SETTING | |
| | | |
| | | |
| Off | Enabled | |
| | | |
| On | Disabled | |
| | | |
| | | |
External Signal Interface: Refer to the Interface Specifications section for information on External Signals.
EXT Print Start Signal Selection (DSW3-5):Allows an external device to initiate a label print for synchronization with the applicator or other external device. When DSW3-5 is On, the unit is in the Continuous print mode, Backfeed is disabled and External Signals are ignored.
| | | |
| DSW3-5 | SETTING | |
| | | |
| | | |
| Off | Disabled | |
| | | |
| On | Enabled | |
| | | |
| | | |
External Signal Type Selection (DSW3-6, DSW3-7): Both the polarity and signal type (level or pulse) of the external print synchronizing signal can be selected.
| | | | | DSW1 |
| DSW3-6 | DSW3-7 | SETTING | |
| | | | | ON | | | | | | | | |
| Off | Off | Type 4 | |
| | | | | OFF | | | | | | | | |
| Off | On | Type 3 | | | | | | | | | |
| | | | | | | | | | | | | |
| On | Off | Type 2 | | 1 2 3 4 5 6 7 8 |
| | | | | | | | | | | | | |
| On | On | Type 1 | | | | | | | | | | |
| | | | | | | | | | | | | |
| | | | | | | | | | | | | |
M84Pro Service Manual | PN: 9001111A | Page 5-6 |