U
PGRADING

F

IRMWARE

VIA

THE

S

ERIAL

P

ORT

B-4

For example, the following screen text shows the download
procedure for a runtime code file:
13. Set your PC’s terminal emulation software baud rate back to
9600 baud. Press <Enter> to reset communications with the
switch.
14. Enter <G> to boot the system.
Restoring Switch Defaults
1. If you have lost your password for management access to the
switch, you can load the default configuration file to restore
the default passwords. When the switch initialization screen
appears, enter firmware-download mode by pressing < ESC>
immediately after the diagnostic test results. Press <Ctrl + G>
followed by <Enter>. The following menu will appear:
Image download at Baudrate [115200]. Please Change your setting
Xmodem Receiving Start ::
Image downloaded to buffer.
[R]untime
[D]iagnostic
[L]oader (Warning: you sure what you are doing?)
Update Image File:r
Runtime Image Filename : acd
Updating file system.
File system updated.
Please change your Baudrate to default then press any key to continue
Enter Selection:
[0]FileManager:
[1]Test Mode Set:
[x] Exit !
Enter Selection:0