9.If using Windows HyperTerminal, click the “Transfer” button, and then click “Send File....” Select the XModem Protocol and then use the “Browse” button to select the required firmware code file from your PC system. The “Xmodem file send” window displays the progress of the download procedure.

10.After the file has been downloaded, you are prompted with “Update Image File:” to specify the type of code file. Press <R> for runtime code, <D> for diagnostic code, or <L> for loader code.

Caution: If you select <L> for loader code, be sure the code is valid. Otherwise the switch will not be able to boot. Unless absolutely necessary do not download loader files.

11.Specify a name for the downloaded code file. Filenames should not contain slashes (\ or /), the leading letter of the file name should not be a period (.), and the maximum length for file names is 31 characters. (Valid characters: A-Z, a-z, 0-9, ".", "-", "_")

12.If you are downloading a runtime code file you must enter the same filename as the current runtime file to overwrite that file. The switch can only contain one runtime file.