7. Instructions
I
Inverter
Expression
Input |
| I |
| Output |
|
| |||
|
| |||
|
|
|
|
|
Function
When the input is OFF, the output is turned ON, and when the input is ON, the output is turned OFF. This instruction inverts the link state.
Execution condition
Input |
| Operation | Output |
OFF | Inverts the input state |
| ON |
ON | Inverts the input state |
| OFF |
Operand
No operand is required.
Example
Y022 comes ON when X000 is OFF, and Y022 comes OFF when X000 is ON.
X000
Y022
Basic Hardware and Function 141