Toshiba 6F3B0250, PROSEC T1 T1S user manual Functional specifications cont’d

Models: PROSEC T1 T1S 6F3B0250

1 313
Download 313 pages 21.99 Kb
Page 49
Image 49

6F3B0250

2. Specifications

Functional specifications (cont’d)

Item

T1-16

T1-28

T1-40

T1-40S

Real-time clock

No

 

 

Yes,

/calendar

 

 

 

(±30 s/month)

Special I/O functions

High speed counter (2 single or 1 quadrature),

 

(Note)

Interrupt input (2 points),

 

 

 

Adjustable analog register (2 points),

 

 

 

Pulse output (CW+CCW or pulse+direction),

 

 

PWM output

 

 

 

Communications

1 port RS-232C (programmer port)

 

 

interface

- for Programmer or Computer link connection

 

 

-

 

 

1 port RS-485

 

 

 

 

- Programmer

 

 

 

 

- Computer link

 

 

 

 

- Data link

 

 

 

 

- Free ASCII

 

-

 

TOSLINE-F10 remote

 

 

 

(by option card)

 

Debug support

Sampling trace

 

 

Sampling trace

function

(8 devices - 256 times or 1 register - 128 times)

(8 devices and

 

 

 

 

3 register - 256

 

 

 

 

times)

 

-

 

 

On-line

 

 

 

 

programming

 

-

 

 

On-line

 

 

 

 

EEPROM write

NOTE

(1)The input specification of the T1-16 (AC power type) is dry contact input, which supplies the power for input signals (24 Vdc) from the unit.

Other types are DC input, which requires external power for input signals.

(2)High speed counter, interrupt input, pulse output and PWM output are available in the DC input types.

(3)High speed counter and interrupt input cannot be used simultaneously.

(4)Pulse output and PWM output cannot be used simultaneously.

Basic Hardware and Function 47