304 T1/T1S User’s Manual
10. Troubl eshooting
Error messa
g
e and related information Special Meanin
g
and countermeasures
Event Info 1 Info 2 Info 3 device
S
y
s RAM check err Error
address Error data Test data S004
S011 In the power-up initialization, an error has
detected b
y
s
y
stem RAM read/write
checkin
g
. (Error down and pro
g
rammin
g
tool
cannot be connected)
Replace the unit if the error remains after
power OFF and ON a
g
ain.
S
y
s ROM BCC error Ille
g
al
BCC S004
S010 BCC error has been detected in the s
y
stem
pro
g
ram in the ROM. (Error down and
pro
g
rammin
g
tool cannot be connected)
Replace the unit if the error remains after
power OFF and ON a
g
ain.
S
y
stem power off Power OFF (no error)
S
y
stem power on Power ON (no error)
Sub-r nestin
g
err Pro
g
ram
t
y
pe -
block No.
Address
in the
block
Sub-r No. T1:
CALL instruction is pro
g
rammed in a
subroutine pro
g
ram. (Error down)
Correct the pro
g
ram.
T1S:
The nestin
g
of subroutines exceeds 3 levels.
(Error do wn)
Correct the pro
g
ram.
WD timer error Address 1 Address 2 S004
S01F The watchdo
g
timer error has occurre d.
(Error down)
If the error occurs frequentl
y
, replace the unit.
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net