Toshiba 6F3B0250, PROSEC T1 T1S user manual FUN Decrement

Models: PROSEC T1 T1S 6F3B0250

1 313
Download 313 pages 21.99 Kb
Page 175
Image 175

6F3B0250

7. Instructions

FUN 045

-1

Decrement

Expression

Input -[ -1 A ]- Output

Function

When the input is ON, the data of A is decreased by 1 and stored in A.

Execution condition

Input

 

Operation

Output

OFF

No execution

 

OFF

ON

Execution

 

ON

Operand

 

Name

 

 

Device

 

 

 

 

 

 

Register

 

 

 

 

Constant

Index

 

 

X

Y

R

S

T.

C.

XW

YW

RW

SW

T

C

D

I

J

K

 

 

A

Operation data

 

 

 

 

 

 

 

Ö

Ö

Ö

Ö

Ö

Ö

Ö

Ö

Ö

 

Ö

Example

At the rising edge of X005 changes from OFF to ON, the data of D0050 is decreased by 1 and stored in D0050.

If the data of D0050 is 1022 before the execution, it will be 1021 after the execution.

D0050

1022

-1

D0050

1021

Note

·There is no limit value for this instruction. When the data of operand A is -32768 before the execution, it will be 32767 after the execution.

Basic Hardware and Function 173

CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Page 175
Image 175
Toshiba 6F3B0250, PROSEC T1 T1S user manual FUN Decrement