COURIER HIGH SPEED MODEMS

AT THE REMOTE MODEM SITE

Remote configuration can be performed at any time during an asynchronous connection. The user performing remote configu- ration can use any modem; it does not have to be a U.S. Robotics model.

1.Make sure the host Courier has been set for remote configuration, as described earlier. Then establish a connection. It does not matter which modem originates the call.

2.After a connection has been established, send the following escape sequence:

Pause four seconds,

type four tildes: ~~~~

and

pause another four seconds.

NOTE: You can change the escape sequence character with Register S42. The pause duration (guard time) can be modified with Register S43. (These values are set at the host Courier modem.)

3.When the Courier begins its login sequence, the caller will see a display similar to the following:

U.S Robotics Courier HST Dual Standard V.34 Fax

Remote Session

Serial Number 000000A000000001

4 . At this point, if password security is active, the caller is prompted for the password.

Password (Ctrl-C to cancel)?.....

As described earlier in Password Security, entering the pass- word assigned by the %P0 command allows viewing privileges only. Entering the password assigned by the %P1 command allows viewing and configuration privileges. Note that there is a 3-minute time limit for entering the password.

D-12 Remote Access

Page 154
Image 154
USRobotics V.34 user manual Password Ctrl-C to cancel?