COURIER HIGH SPEED MODEMS

ALLOWABLE VOICE/DATA SWITCH FUNCTIONS

Use Register S32 to set the voice/data switch for the function you desire. The default is S32=1pressing the switch forces the modem off hook in Originate mode. Pressing the switch when you power on the modem causes it to perform a power-on self- test. See Table G.1S32 Functions below.

NOTE: Some of the applications listed below require some sort of preconfiguration. Review the Chapter/Appendix referenced before using the Voice/Data switch function.

S32 Value

Voice/Data Switch Function

Related Command

0

Disabled

_

1

Voice/DataOriginate Mode (Default*)

ATD (Appendix G)

2

Voice/DataAnswer Mode

ATA (Appendix G)

3

Redial Last Number

ATDL (Chapter 4)

4

Dial Number Stored at position 0

ATDS0 (Chapter 4)

5

Auto Answer On/Off Toggle

ATS0=0 or 1 (Chapter 4)

6

Reset Modem

ATZ (Chapter 4)

7

Initiate Remote Digital Loopback

AT&T6, S16=8

 

 

(Appendix H)

8

Busy Out Phone Line Toggle

_

9

Execute Stored Command (Default*)

AT&ZC=s (Chapter 4,

Appendix F, G)

*The modem is shipped from the factory set at S32=9. If a command string has been stored (&ZC=s), the modem executes the stored command string when the voice/data switch is pushed. If no command string is stored, the modem still reports that S32=9, but actually behaves as if it is set to S32=1, Originate mode.

Table G.1S32 Functions