COURIER HIGH SPEED MODEMS

Additional Result Code Subsets

NOTE: ARQ (Automatic Repeat Request) is used in this manual to denote calls under error control.

&An Enable/disable additional result code subsets. See the Xn command earlier in this chapter.

&A0

ARQ result codes are disabled. This setting does not

 

affect an error control connection; the modem returns the

 

standard CONNECT messages if result codes are

 

enabled.

 

&A1

ARQ result codes are enabled, indicating that a

 

connection is under error control. Message 14 is

 

displayed if the modem is set to X0 and the connection is

 

at any rate from 1200 to 28.8K bps. The remaining results

 

indicate the connection rate and require a setting of X1 or

 

higher.

 

 

14/CONNECT/ARQ

57/CONNECT 16800/ARQ

 

15/CONNECT 1200/ARQ

88/CONNECT 19200/ARQ

 

16/CONNECT 2400/ARQ

94/CONNECT 21600/ARQ

 

17/CONNECT 9600/ARQ

100/CONNECT 24000/ARQ

 

19/CONNECT 4800/ARQ

104/CONNECT 26400/ARQ

 

22/CONNECT 12000/ARQ

108/CONNECT 28800/ARQ

 

24/CONNECT 7200/ARQ

 

 

26/CONNECT 14400/ARQ

 

&A2

Additional VFC, V34, HST, or V32 modulation indicator.

 

Included for users of HST Dual Standard modems. If

 

your software cannot handle the added modulation

 

information, select &A1 or &A0.

23/CONNECT 9600/HST

27/CONNECT 9600/ARQ/HST

28/CONNECT 4800/HST

29/CONNECT 4800/ARQ/HST

30/CONNECT 7200/HST

34/CONNECT 7200/ARQ/HST

31/CONNECT 12000/HST

32/CONNECT 12000/ARQ/HST

35/CONNECT 14400/HST

36/CONNECT 14400/ARQ/HST

53/CONNECT 16800/HST

57/CONNECT 16800/ARQ/HST

33/CONNECT 9600/V32

37/CONNECT 9600/ARQ/V32

38/CONNECT 4800/V32

39/CONNECT 4800/ARQ/V32

40/CONNECT 7200/V32

44/CONNECT 7200/ARQ/V32

41/CONNECT 12000/V32

42/CONNECT 12000/ARQ/V32

45/CONNECT 14400/V32

46/CONNECT 14400/ARQ/V32

83/CONNECT 16800/V32

84/CONNECT 16800/ARQ/V32

87/CONNECT 19200/V32

90/CONNECT 19200/ARQ/V32

Data Mode Operations 4-17

Page 54
Image 54