COURIER HIGH SPEED MODEMS

Register

Default

Function

S0

See DIP

Sets the number of rings on which to

 

Switch 5

answer when in Auto Answer mode. S0=0

 

 

disables Auto Answer, the same as DIP

 

 

switch 5 ON (factory setting). S0=1

 

 

enables Auto Answer and the modem

 

 

answers on the first ring.

 

 

NOTE: If DIP switch 5 is OFF and S0=0,

 

 

Auto Answer remains disabled.

S1

0

Counts and stores the number of rings

 

 

from an incoming call.

S2

43

Stores the ASCII decimal code for the

 

 

escape code character. Default character is

 

 

“+”. A value of 128-255 disables the

 

 

escape code.

S3

13

Stores the ASCII decimal code for the

 

 

Carriage Return character. Valid range is

 

 

0127.

S4

10

Stores the ASCII decimal code for the Line

 

 

Feed character. Valid range is 0127.

S5

8

Stores the ASCII decimal code for the

 

 

Backspace character. A value of 128-255

 

 

disables the Backspace key's delete

 

 

function.

S6

2

Sets the number of seconds the modem

 

 

waits before dialing. If set to X2, X4, X6,

 

 

or X7, the modem dials as soon as it

 

 

detects a dial tone (fast dials). If there is

 

 

no dial tone, the modem observes the

 

 

normal S6 timeout.

S7

60

Sets the number of seconds the modem

 

 

waits for a carrier. May be set for much

 

 

longer duration if, for example, the

 

 

modem is originating an international

 

 

connection.

B-16 Summaries and Tables