COURIER HIGH SPEED MODEMS
Register | Default | Function |
S39−S40 | 0 | Reserved. |
S41 | 0 | Sets the number of allowable remote |
|
| access login attempts, thus enabling or |
|
| disabling remote access. The default |
|
| setting of zero allows no remote login |
|
| attempts, thus disabling remote access. A |
|
| value of 1 or greater enables remote |
|
| access. If the number of unsuccessful |
|
| login attempts exceeds the limit set by this |
|
| register, the modem returns online and |
|
| any further login attempts during the |
|
| remainder of that connection are refused. |
S42 | 126 | Stores the ASCII decimal code for the |
|
| remote access escape character. The |
|
| default character is a tilde (~). |
S43 | 200 | Sets the duration, in fiftieths of a second, |
|
| of the guard time for the remote access |
|
| (~~~~) sequence. |
S44 | 15 | Sets the duration, in seconds, of the delay |
|
| between when the modem senses loss of |
|
| carrier and when it attempts to re- |
|
| establish a |
S45−S50 | 0 | Reserved. |