COURIER HIGH SPEED MODEMS
Register Default Function
7128 Unusual software incompati- bility. Some software may not accept 7200, 12000, 14400, 16800, 19200 and 21600 bps result codes. This setting disables the codes and displays the 9600 code instead. The call's actual rate can be viewed on the ATI6 screen.
Error control handshaking options: select the total values of bits 4 and 5.
Bit 4 Bit 5 Result
00 Complete handshaking sequence: V.42 Detection, LAPM error control, MNP
16 0 Disable MNP
032 Disable V.42 Detection and
LAPM
1632 Disable Detection phase, if you know that the remote modem does LAPM, but not the Detection phase.
S28 | 8 | Sets the duration, in tenths of a second, of |
|
| the extra 3000/600 Hz answer tones sent |
|
| during V.32 handshaking. This gives V.32 |
|
| modems additional time to connect in V.32 |
|
| mode before timing out. |
If there is difficulty answering older, manually operated V.32 modems, for example, modems that require a button to be pushed in order to dial, try lengthening the duration of the extra tones.