Section 4, User Interface Guide ATLAS 550 System Manual
108 © 2002 ADTRAN, Inc. 61200305L1-1F
MODULES (T1/PRI-1) > CONFIGURATION
Write security:3; Read security: 5
All of the following configurable parameters apply to whether the port is connected to a Primary Rate
ISDN circuit or a channelized T1 circuit.
MODULES (T1/PRI-1) > CONFIGURATION > PRT
Read security: 5
Displays the port number.
MODULES (T1/PRI-1) > CONFIGURATION > PORT NAME
Write security: 3; Read security: 5
Accepts any alpha-numeric name up to 16 characters long, to uniquely identify each port on the
ATLAS 550.
MODULES (T1/PRI-1) > CONFIGURATION > FRAME
Write security: 2; Read security: 5
This field must be set to match the frame format of the circuit to which it is connected, available from the
network supplier. Choose either D4 or ESF.
MODULES (T1/PRI-1) > CONFIGURATION > CODE
Write security: 2; Read security: 5
Set this field to match the line code of the circuit to which it is connected (this information is available
from the network supplier). Choose either AMI (Alternate Mark Inversion) or B8ZS (Bipolar Eight Zero
Substitution).
MODULES (T1/PRI-1) > CONFIGURATION > TX YEL
Write security: 3; Read security: 5
Controls the transmission of yellow alarms. Choose either ON or OFF.
MODULES (T1/PRI-1) > CONFIGURATION > TX PRM
Write security: 3; Read security: 5
Controls the sending of performance report messaging (PRM) data on the facility data link (FDL). The
PRM data continues to be collected even if XMIT PRM is turned off (possible only with ESF format).
Choose either ON or OFF.
MODULES (T1/PRI-1) > CONFIGURATION > LBO
Write security: 2; Read security: 5
Selects the Line Build Out (LBO) for the network interface. When connecting an ATLAS 550 port to a
DSX-1 interface, this parameter is typically set to match the distance (in feet) between the ATLAS 550 and
the device with which it is connecting. When you select this item, a list of choices displays (0 dB, -7.5 dB,
-15 dB, -22 dB, 266 FT, 399 FT, 533 FT, 655 FT). Select the appropriate option.