ATLAS 550 System Manual Section 7, System Event Logging
61200305L1-1F © 2002 ADTRAN, Inc. 381
3. SYSTEM EVENTS

The following tables provide a listing of ATLAS system events. This includes tables of events for each

category, according to the order they appear in the EVENT LOG setup screen.

EVENT LOG messages may be sent to an external Syslog server for storage. Refer to

DLP-013, “Using the ADTRAN Utility Syslog with the ATLAS 550” for more details.

Table 1. System Controller Events
Console Log String Category Event
“-24 V Power Failure Cleared” CRITICAL -24 V power supply is functioning normally
again
“-24 V Power Failure” CRITICAL -24 V power supply is not operating properly
“-58 V Power Failure Cleared” CRITICAL -58 V power supply is functioning normally
again
“-58 V Power Failure” CRITICAL -58 V power supply is not operating properly
>70 Internal Temperature Warning Cleared CRITICAL Internal system temperature has cooled
below 70o C
>85 Internal Temperature Warning Cleared CRITICAL Internal system temperature has cooled
below 85o C
>70C Internal Temperature Warning CRITICAL Internal system temperature is greater than
70o C
>85C Internal Temperature Warning CRITICAL Internal system temperature is greater than
85o C
Firmware invalid CRITICAL Corrupted firmware
Firmware update failed CRITICAL Flash download failed
System Configuration Uploaded CRITICAL ATLAS configuration file loaded into the
system and activated
Module Not Responding WARNING Module removed or not responding
ACO Switch pressed MINOR ACO switch pressed
External Alarm Detected MINOR Alarm detected on External Alarm Monitor
Login Failure MINOR Console login failure1
External Alarm Cleared MINOR External alarm cleared
Timing source changed to Internal MINOR Neither the primary nor the backup are valid
Timing source changed to Backup MINOR The primary source is not Backup valid
Timing source changed to Primary MINOR The timing source changed to primary
Not responding to programming MINOR Unable to program module