ATLAS 550 System Manual Section 4, User Interface Guide
61200305L1-1F © 2002 ADTRAN, Inc. 137
MODULES (V35NX-2) > TEST > CLR
Write security: 4; Read security: 4
Clears error counters on test pattern results menu.
MODULES MENU (DUAL USSI OPTION MODULE)
The ATLAS 550 system controller automatically detects the presence of the Dual USSI Option Module
when it is installed in the system (listed as USSI-2). To see the menus for the Dual USSI Option Module
via the terminal menu, use the arrow keys to scroll to the MODULES menu and press <Enter> to access the
module choices. Refer to the Dual USSI Option Module Quick Start Guide for a menu tree containing a
complete listing of menus.
MODULES (USSI-2) > INFO
Read security: 5
Provides information about the module part number, serial number, and assembly revision.
MODULES (USSI-2) > INFO > PART NUMBER
Read security: 5
Displays the part number of the module.
MODULES (USSI-2) > INFO > SERIAL NUMBER
Read security: 5
Displays the serial number of the module.
MODULES (USSI-2) > INFO > ASSEMBLY REVISION
Read security: 5
Displays the assembly revision of the installed module.
MODULES (USSI-2) > ALARM STATUS
Read security: 5
Displays the current alarm status.
MODULES (USSI-2) > ALARM STATUS > PRT
Read security: 5
Indicates the port number. There are 2 available interfaces on the Dual USSI Option Module.