Section 4, User Interface Guide ATLAS 550 System Manual
304 © 2002 ADTRAN, Inc. 61200305L1-1F
DIAL PLAN (PKT ENDPT - PACKET ENDPOINTS)DIAL PLAN (PKT ENDPT) > USER TERM
Write security: 3; Read security: 5

This menu allows the user to define option parameters for ports configured as packet endpoints.

DIAL PLAN (PKT ENDPT) > USER TERM > IFCE CONFIG
Write security: 3; Read security: 5
Specifies the configuration parameters for the endpoint.
DIAL PLAN (PKT ENDPT) > USER TERM > IFCE CONFIG > OUTDIAL NUMBER
Write security: 3; Read security: 5

Defines the number dialed to originate a call.

DIAL PLAN (PKT ENDPT) > USER TERM > IFCE CONFIG > OUTGOING CALL TYPE
Write security: 3; Read security: 5

Selects the terminating resource type, either DIGITAL 64K or DIGITAL 56K.

DIAL PLAN (PKT ENDPT) > USER TERM > IFCE CONFIG > REDIAL TIMER
Write security: 3; Read security: 5

Selects the time delay in seconds between redial attempts.

SPID NUMBER
Write security: 3; Read security: 5

Defines the SPID number(s) used for this BRI line. Although the value of the SPID is not significant,

a SPID must be entered for each phone number. For convenience, the SPID can be set to be the same

as the phone number. The Quad BRI S/T Module does not support autoSPID detection software

which some terminal adapters offer.

No SPID Number is needed for the Euro-ISDN Switch Type.

CALLS
Write security: 3; Read security: 5

For User terminations, the number of calls is fixed at 2.

D64, D56, AUDIO, SPEECH

Write security: 3; Read security: 5

These options reflect the network provisions for this SPID. If the BRI was purchased with different

services provisioned for the SPIDs, then the call must match the services supported.