Section 4, User Interface Guide ATLAS 550 System Manual
234 © 2002 ADTRAN, Inc. 61200305L1-1F
DEDICATED MAPS > CREATE/EDIT MAPS
Write security: 3; Read security: 5

Creates new maps and defines settings, as well as edits existing maps. To add a new map, position the

cursor in the index column and press < I >. ATLAS 550 automatically names the maps in the sequence in

which they are created. You can change the names with MAP NAME.

DEDICATED MAPS > CREATE/EDIT MAPS > #
Write security: 3; Read security: 5

Displays the index number of the available maps.

DEDICATED MAPS > CREATE/EDIT MAPS > MAP NAME
Write security: 3; Read security: 5

Displays the name of the dedicated map. The name can contain up to 57 alpha-numeric characters,

including spaces and special characters. To edit the name, press <Enter> and type in the new name.

DEDICATED MAPS > CREATE/EDIT MAPS > SORT TO/FROM
Write security: 3; Read security: 5

Specifies sort order based on the end points set in CONNECTS/FROM CONFIG and CONNECTS/TO CONFIG. You

can also turn OFF this option. The sort feature is helpful when you are attempting to find a particular

connection in a large connection list.

DEDICATED MAPS > CREATE/EDIT MAPS > CONNECTS
Write security: 3; Read security: 5
Enters the dedicated map connections. Press <Enter> to activate the submenus.
DEDICATED MAPS > CREATE/EDIT MAPS > CONNECTS > FROM SLT
Write security: 3; Read security: 5

Specifies the slot to use for the FROM connection. When you select this option, a list of all of the slots and

the modules installed in the slots displays. Select the appropriate slot and press <Enter>.

Some of the options available in this submenu change depending on the type of modules

selected in the FROM or TO fields. For more information on these submenus, refer to the

individual module discussions in this section.