Section 5, DLP-012

ATLAS 550 System Manual

 

 

DLP-012

Perform Steps Below in the Order Listed

1.Mount the modem in its permanent position.

2.Connect power to the modem using manufacturer instructions.

3.Configure the modem as follows:

Speed

9600 bps

Data bits

8

Parity

none

Stop bits

1

Flow control

hardware

Auto answer

on

DTR

ignore

4.Connect the male RJ-45 connector of the data cable to the female RJ-45 connector, labeled CONTROL IN, located on the lower right corner of the back of the unit or to the CRAFT port, located on the lower left of the front of the unit.

5.Route the data cable to the modem.

6.Connect the other end of the cable to the RJ-45 end of the connector (RJ-45 to male DB-25). Then, connect the DB-25 end of the connector to the modem, configured as described above.

7.Connect the modem to the POTS line as required by the manufacturer.

8.Login to the ATLAS 550 system. (Refer to DLP-002for detailed instructions).

9.From the MAIN MENU, select the SYSTEM CONFIG menu and press the right arrow key to enter the right-pane menus.

10.From the SYSTEM CONFIG menu, select the CHAIN PORT menu and press <Enter>. Once in the CHAIN PORT menus, press the right arrow key to enter the right-pane menus.

11.From the CHAIN PORT menus, select the PORT TYPE menu and select DIAL.

If you are connected to the ATLAS 550 using the CRAFT or CONTROL IN interfaces, changing the PORT TYPE mode to DIAL will terminate your session. You MUST have Ethernet access to the ATLAS 550 to change the PORT TYPE back to DIRECT and restore your terminal session.

To complete the connection to the unit, the ATLAS 550 must now be called from a PC configured to emulate a VT100 terminal, with communication software set as in step 3 and configured for DIAL mode.